What is an RO Flow Restrictor and When to Change?

What is Flow Restrictor?

A flow restrictor, as the name suggests, restricts the flow of RO reject water.

Amazon Great Summer Sale

The flow restrictor maintains high pressure inside the RO membrane (a precondition for RO purification) by creating back pressure on the membrane and also controls the recovery ratio of the purifier.

If the flow restrictor is not used then the high-pressure water coming in from the booster pump will flow unrestricted from the reject outlet of the RO membrane.

This will result in low pressure inside the RO membrane and higher wastage of water. RO membrane won’t be able to work if the pressure inside the RO membrane is not high.

RO Flow Restrictor
An RO Flow Restrictor of 550 mL

See the below water flow diagram of an RO water purifier to understand the working of a flow restrictor.

Flow Restrictor in RO Water Purifier
Flow Restrictor in RO Water Purifier

Flow restrictors are generally available in different flow ratings and must be properly sized according to the capacity of the RO membrane.

How to Find a Matching Flow Restrictor?

The ratings that you see on flow restrictors, like FR 200, FR 300, FR 450, indicate the flow rate, in mL per minute (Millilitres Per Minute).

RO membrane capacity is given in GPD (Gallons Per Day).

1 Gallon is approximately equal to 3.78 litres.

Generally, the flow restrictor value should be 4 times the production rating or the capacity of the membrane.

In order to find a matching flow restrictor, first, we need to convert the flow restrictor’s capacity value into GPD.

This is quite simple, and all you need to do is simply multiply the flow restrictor capacity in mL per minute by 0.38 to convert it into GPD.

Example of Flow Restrictor for 800 mL is:

800 x 0.38 = 304 GPD

As we know the flow restrictor rating should be 4 times the RO membrane.

Dividing the above rating by 4 i.e. 304/4, we get 76 GPD. So for an RO membrane of 75-80 GPD, you should use an 800 mL flow restrictor.

In India, most technicians are using Flow Restrictor 450 with 75 GPD or 80 GPD RO membrane. But, we recommend a flow restrictor of at least 550 ml.

The recommended flow restrictor sizes are listed in the below table.

Membrane Size (in GPD)Flow Restrictor (mL per minute)
18200
25250
36250 or 360
50420 or 525
75550 to 800
80800
1001000

If you are looking to replace the flow restrictor of your water purifier then you can check on Amazon.in.

What if I use a Flow Restrictor of a Higher or Lower Capacity?

The RO membrane GPD and flow restrictor capacity must be matched to keep a proper balance between water wastage and purification quality. If they are not matched, this can cause excessive wastage of water or may reduce the life of the RO membrane.

Under Sizing

If you are using a lower capacity flow restrictor for a higher capacity membrane then it will result in early choking of the RO membrane, reduced membrane life, and an increase in the TDS value of the purified water.

Over-Sizing

And if you use a higher capacity flow restrictor then it will result in higher wastage of water and lower pressure inside the RO membrane. Low pressure inside an RO membrane can have an adverse effect on the quality of purification.

When to Change the Flow Restrictor?

We recommend that the flow restrictor should be replaced every time an RO membrane is replaced. Because over time, like RO membrane and filters, flow restrictors can also get choked because of scale build-up.

And if the new RO membrane is of a different capacity then also the flow restrictor must be changed according to the capacity of the RO membrane.

Pramod

An engineering graduate from a top Indian university, boasts a decade-long expertise in reviewing home appliances, particularly water purifiers. As the Editor-in-Chief of BestROWaterPurifier.in, his insights empower readers with valuable advice for healthier choices in household essentials.

21 Comments
  1. An RO membrane is like a balanced equation. The more waste water the less product water. You should keep the restriction with in 10% of the ratio, 4.1 to 1 or 3.9 to 1. Running the restrictor rich makes the membrane last longer.

  2. Waste water has cease to come out from my RO machine drain pipe although it’s giving purified water of tds 34 from input water of tds value of 113. Plz suggest the faulty component.

  3. Flow restrictor for 300GPD membrane on 300GPD Pump.

  4. Thanks for sharing the valuable data (knowledge) on flow restrictor. I wonder why technician used 450mlm for 75/80 gpd membrane. To replace the membrane often right. My membrane is 100gpd and using 450FR shall I change into 550FR or 800FR pls suggest. Technician telling that if you are using higher flow restrictor the higher pressure will lead to higher waste water out. And also what is the combination of pump having 110Psi output and membrane/flow restrictor.
    Thanks & Regards
    M.Thulasiraman

    • You can use 450FR with 100GPD membrane but it may reduce the life of the RO membrane by early choking of the RO membrane. It may also increase the TDS value of the purified water.

      If the incoming water has very high TDS and if you are concerned about the life of RO membrane then use a flow restrictor of higher value. But, if you are not concerned much about the life of RO membrane but would like to reduce the RO waste water then you can go for a flow restrictor of lower value.

1 2

Leave a reply

Best RO Water Purifier
Logo
Register New Account
Compare items
  • Water Purifiers (0)
Compare